ACI Flammability Testing Services

ACI has in-house laboratory facilities to undertake a range of regulatory flammability tests required for design compliance and ongoing production batch conformity.
ACI also offers a CVE delegation service, allowing one of ACI's in-house CVE's to witness flammability testing on behalf of a delegating design organisation.
The full suite of flammability testing and additional services ACI offer are detailed below.
To discuss ACI's testing services please email rfq@airlinecomponents.com

ACI Test Code Description Specification RFQ
Test Code Description Specification RFQ
SI001-01 (F1) 60s Vertical CS 25.853(a), App F, Part 1(a)(1)(i)
SI001-02 (F2) 12s Vertical CS 25.853(a), App F, Part 1(a)(1)(ii)
SI001-03 (F3) 64mm/min Horiz’l CS 25.853(a), App F, Part 1(a)(1)(iv)
SI001-04 (F4) 102mm/min Horiz’l CS 25.853(a), App F, Part 1(a)(1)(v)
SI001-05 (F5) 45° Test CS 25.853(a), App F, Part 1(a)(2)(ii)
SI001-06 (F6) 60° Test CS 25.853(a), App F, Part 1(a)(3)
SI001-10 (F7) Heat Release CS 25.853(d), App F Part IV
SI001-20 (F8) Smoke Density CS 25.853(d), App F Part V (flaming)
SI001-21 (F9) Smoke Density ABD0031 Iss F, Para 7.3 (AITM2-0007) (flaming)
SI001-22 (F9) Smoke Density ABD0031 Iss F, Para 7.3 (AITM2-0007) (non-flaming)
SI001-23 (F9) Smoke Density Boeing D6-51377 Rev G, 4.1(b)(3), Table 2 (BSS 7238) (flaming)
SI001-30 (F10) Toxicity Test ABD0031 Iss F, Para 7.4 (AITM 3.0005) (flaming)
SI001-31 (F10) Toxicity Test ABD0031 Iss F, Para 7.4 (AITM 3.0005) (non-flaming)
SI001-32 (F10) Toxicity Test Boeing D6-51377 Rev G, 4.1(b)(3), Table 1 (BSS 7239)

ADDITIONAL SERVICES

ACI DOA Part 21J Consultancy
Our team has a huge wealth of experience in cabin interiors & would always be pleased to provide assistance with any project. We are specialists in product design, development & manufacture & using these skills we have developed an unrivalled database of compliant materials & ‘how to’ knowledge that can be translated to advise & guide you through any scenario.

ACI CVE Delegated Witnessing
ACI CVE delegated witnessing is a service to use ACI in-house CVE’s for witnessing of flammability testing. This is often more cost effective than the travel expenses & time lost in sending third-party Part 21J CVE’s to witness flammability testing.

Training
With over 50 years of industry experience our Chief of the Office of Airworthiness & Quality Manager can deliver training & consultancy, anywhere in the world, to keep your team up-to-date with necessary Part 21 regulatory developments. The training can be tailored to suit staff in different roles & various levels of seniority within a company.